OD:Φ9.2×ID:Φ7.5×L:1045 |
OD:Φ9.8×ID:Φ8.0×L:1025 |
OD:Φ10.8×ID:Φ8.7×L:1020 |
OD:Φ9.2×ID:Φ7.3×L:1045 |
OD:Φ9.2×ID:Φ7.3×L:1080 |
OD:Φ10.2×ID:Φ8.6×L:1030 |
OD:Φ10.2×ID:Φ8.4×L:1020 |
OD:Φ10.2×ID:Φ8.6×L:1035 |
OD:Φ9.2×ID:Φ7.4×L:1032 |
OD:Φ9.0×ID:Φ7.4×L:1030 |
OD:Φ5.3×ID:Φ4.4×L:1096 |
OD:Φ6.5×ID:Φ5.5×L:1017 |
OD:Φ5.7×ID:Φ4.9×L:1090 |
OD:Φ5.8×ID:Φ4.8×L:1090 |
OD:Φ9.2×ID:Φ7.3×L:1035 |
OD:Φ9.0×ID:Φ7.3×L:1025 |
OD:Φ9.5×ID:Φ7.8×L:1050 |
OD:Φ9.4×ID:Φ7.7×L:1030 |
OD:Φ9.4×ID:Φ7.6×L:1030 |
OD:Φ12.75×ID:Φ10.75×L:1246 |
OD:Φ11.9×ID:Φ9.85×L:1246 |
OD:Φ11.4×ID:Φ9.5×L:1245 |
OD:Φ13×ID:Φ10.8×L:1285 |
OD:Φ13.2×ID:Φ10.9×L:1285 |
OD:Φ12.9×ID:Φ10.5×L:1640 |
OD:Φ12.85×ID:Φ10.7×L:1280 |
OD:Φ12×ID:Φ9.8×L:1285 |
OD:Φ12.2×ID:Φ9.8×L:1300 |
OD:Φ11.3×ID:Φ9.05×L:1291 |
OD:Φ12.2×ID:Φ9.8×L:1680 |
OD:Φ12.0×ID:Φ9.8×L:1290 |
OD:Φ10.7×ID:Φ8.63×L:1300 |
OD:Φ10.7×ID:Φ9.0×L:1303 |
OD:Φ10.6×ID:Φ8.6×L:1350 |
OD:Φ12.95×ID:Φ10.5×L:1300 |
OD:Φ12.1×ID:Φ9.84×L:1280 |
OD:Φ11.3×ID:Φ9.2×L:1350 |
OD:Φ12.95×ID:Φ10.5×L:1280 |
OD:Φ12.95×ID:Φ10.5×L:1290 |
OD:Φ11.5×ID:Φ9.5×L:1230 |
OD:Φ10.8×ID:Φ8.6×L:1210 |
OD:Φ12.0×ID:Φ9.8×L:1230 |
OD:Φ5.2×ID:Φ4.3×L:362 |
OD:Φ3.5×ID:Φ2.7×L:305 |
OD:Φ5.3×ID:Φ4.4×L:360 |
OD:Φ5.5×ID:Φ4.45×L:355 |
OD:Φ6.3×ID:Φ5.3×L:370 |
OD:Φ5.5×ID:Φ4.5×L:366 |
OD:Φ5.2×ID:Φ4.3×L:382 |
OD:Φ5.3×ID:Φ4.3×L:586 |
OD:Φ5.2×ID:Φ4.3×L:592 |
OD:Φ5.15×ID:Φ4.25×L:533 |
OD:Φ6.2×ID:Φ5.15×L:576 |
OD:Φ6.2×ID:Φ5.15×L:545 |
OD:Φ6.3×ID:Φ5.2×L:535 |
OD:Φ5.2×ID:Φ4.3×L:607 |
OD:Φ4.15×ID:Φ3.2×L:600 |
OD:Φ3.25×ID:Φ2.6×L:610 |
OD:Φ3.3×ID:Φ2.6×L:680 |
OD:Φ9.6×ID:Φ7.75×L:1060 |
OD:Φ10×ID:Φ8.1×L:1068 |
OD:Φ9.4×ID:Φ7.7×L:1059 |
OD:Φ6.2×ID:Φ5.0×L:1104 |
OD:Φ9.3×ID:Φ7.4×L:1075 |
OD:Φ10.8×ID:Φ8.6×L:1007 |
OD:Φ8.2×ID:Φ6.6×L:1087 |
OD:Φ9.6×ID:Φ7.6×L:1090 |
OD:Φ9.5×ID:Φ7.6×L:1090 |
OD:Φ9.7×ID:Φ7.9×L:1052 |
OD:Φ11.8×ID:Φ10.0×L:1057 |
OD:Φ6.2×ID:Φ4.9×L:1090 |
OD:Φ9.5×ID:Φ7.6×L:1008 |
OD:Φ9.8×ID:Φ7.8×L:1070 |
OD:Φ12.0×ID:Φ9.8×L:1054 |
OD:Φ12.9×ID:Φ10.5×L:1255 |
OD:Φ13×ID:Φ10.5×L:1255 |
OD:Φ12.9×ID:Φ10.6×L:1242 |
OD:Φ12.95×ID:Φ10.5×L:1448 |
OD:Φ12.9×ID:Φ10.7×L:1251 |
OD:Φ11.35×ID:Φ9.6×L:1254 |
OD:Φ12.9×ID:Φ10.5×L:1295 |
OD:Φ12.9×ID:Φ10.5×L:1450 |
OD:Φ12.9×ID:Φ10.5×L:1450 |
OD:Φ5.35×ID:Φ4.4×L:561 |
OD:Φ6.15×ID:Φ5.06×L:560 |
OD:Φ5.4×ID:Φ4.45×L:404 |
OD:Φ10×ID:Φ8.1×L:1081 |
OD:Φ10.2×ID:Φ8.1×L:1045 |
OD:Φ10.2×ID:Φ8.1×L:1059 |
OD:Φ13×ID:Φ10.55×L:1465 |
OD:Φ12.9×ID:Φ10.75×L:1500 |
OD:Φ11.7×ID:Φ9.5×L:1453 |
OD:Φ13.4×ID:Φ10.7×L:1465 |
OD:Φ13×ID:Φ10.5×L:1440 |
OD:Φ12.8×ID:Φ10.6×L:1371 |
OD:Φ10.7×ID:Φ8.9×L:1255 |
OD:Φ11.2×ID:Φ8.7×L:1256 |
OD:Φ4.1×ID:Φ3.18×L:315 |
OD:Φ5.05×ID:Φ4.05×L:300 |
OD:Φ5.2×ID:Φ4.3×L:355 |
OD:Φ5.2×ID:Φ4.4×L:355 |
OD:Φ5.3×ID:Φ4.38×L:585 |
OD:Φ5.15×ID:Φ4.3×L:600 |
OD:Φ5.4×ID:Φ4.4×L:600 |
OD:Φ4.25×ID:Φ3.5×L:618 |
OD:Φ3.7×ID:Φ2.8×L:625 |
OD:Φ3.3×ID:Φ2.7×L:610 |
OD:Φ3.18×ID:Φ2.5×L:621 |
OD:Φ4.1×ID:Φ3.1×L:600 |
OD:Φ5.2×ID:Φ4.3×L:360 |
OD:Φ5.4×ID:Φ4.3×L:362 |
OD:Φ4.15×ID:Φ3.2×L:365 |
OD:Φ3.7×ID:Φ2.8×L:625 |
Das Einführrohr des Endoskops ist ein wichtiges Unterscheidungsmerkmal unter den Endoskopen, die für die Gastroenterologie entwickelt wurden.Obwohl es je nach Anwendung des Endoskops offensichtliche Unterschiede gibt (siehe Tabelle 2).Die Unterschiede zwischen den verschiedenen Endoskopmodellen sind ebenso wichtig.Dies gilt insbesondere für Darmspiegel obwohl Endoskopisten aus verschiedenen Gründen ein bestimmtes Kolonoskopmodell bevorzugen können,Die Eigenschaften des Instruments und des Einführrohrs führen dazu, dass ein Endoskopist sich eher für ein bestimmtes Kolonoskop entscheidet.Wenn eine einzelne Spezifikation des Geräts die Geschwindigkeit und Leichtigkeit bestimmen kann, mit der der Endoskopist das Gerät einführen kann, dann sind es die mechanischen Eigenschaften des Einführrohrs.
Das Einführrohr enthält in der Regel (1) Röhren zur Saugung (Biopsie), Luft- und Wasserzufuhr; (2) oftmals ein zusätzliches Rohr für einen vorwärts gerichteten Wasserstrahl; (3) vier Winkelsteuerleitungen;(4) feine elektrische Drähte, die den Bildsensor der Ladungskopplungsvorrichtung (CCD) an der distalen Spitze des Endoskops mit dem Videoprozessor verbinden; und (5) empfindliche Glasfasern, die Licht von der Lichtquelle zum distalen Ende des Endoskops bringen.Kolonoskope mit verstellbarer Flexibilität des Insertionsrohrs verfügen über eine zusätzliche Komponente einen Spanndraht zur Steuerung der Steifheit des InsertionsrohrsDie Duodenoskope verfügen außerdem über eine zusätzliche Draht-/Spule-Hülle, die die Länge des Einführrohrs durchläuft, um die Auf- und Abstellung des Fingerspitzels zu steuern.
Treten Sie mit uns jederzeit in Verbindung